Video
Elektr sxemasi

Manba kodi
1// ─────────────────────────────────────────
2// BlueGrays · bluegrays.com
3// Night Light with Ldr
4// ─────────────────────────────────────────
5// Turns the LED on automatically when it gets dark. The LDR voltage
6// divider is read on A0; when the value drops below 50 (dark) the LED on
7// D13 turns on, and it turns off in the light.
8//
9// Pins:
10// D13 -> LED (with a 330 ohm resistor)
11// A0 -> Junction of the LDR and the 10k resistor
12// LDR other leg to 5V, 10k other leg to GND
13
14int value; // Light reading (0-1023)
15
16void setup() {
17 pinMode(13, OUTPUT); // LED output
18}
19
20void loop() {
21 value = analogRead(A0); // Read the light level
22
23 // Threshold 50: anything below counts as dark. Tune the sensitivity with this number
24 if (value < 50) {
25 digitalWrite(13, HIGH); // Dark: LED on
26 } else {
27 digitalWrite(13, LOW); // Bright: LED off
28 }
29}
30
Ko‘p so‘raladigan savollar
Chegaraviy qiymatni qanday aniqlayman?
Qiymatlarni ko‘rish uchun avval setup() ichiga `Serial.begin(9600);`, loop() ichida esa `value = analogRead(A0);` qatoridan darhol keyin `Serial.println(value);` qo‘sh, so‘ng Serial Monitorni 9600 baudda och. Muhit yorug‘ va qorong‘i bo‘lgandagi qiymatlarni yozib qo‘y. Agar ulanish qorong‘ida pastroq qiymat bersa, `if (value < 50)` ichidagi 50 ni shu ikki qiymat orasidan tanlangan chegaraga almashtir.
LED chegara atrofida miltillayapti. Buning oldini qanday olaman?
Yorug‘lik darajasi chegaraviy qiymat atrofida bo‘lganda, kichik tebranishlar LED-ni yoqib-o‘chiraveradi. Ikki xil chegara ishlatsang (biri yoqish, biri o‘chirish uchun, masalan, 400 va 450), ya’ni gisterezis qo‘shsang, miltillash yo‘qoladi.
LED LDR-ni yoritib, o‘zini o‘zi o‘chirib qo‘yyapti. Nima qilay?
LED nuri LDR-ga tushsa, sensor atrofni yorug‘ deb hisoblaydi. LDR-ni LED-dan uzoqroqqa yoki unga qaramaydigan qilib joylashtir; kerak bo‘lsa, LDR atrofiga kichik to‘siq yasa.
Bu usul bilan haqiqiy chiroqni yoqsam bo‘ladimi?
Ha, LED o‘rniga rele moduli ulab, 220 V li chiroqni boshqarishing mumkin. Tarmoq kuchlanishi xavfli; ulanishlarni qurilma tarmoqdan uzilgan holda bajar va kattalardan yoki elektrikdan yordam so‘ra.